Skip to content Skip to sidebar Skip to footer

Case Study: From Parameter Verification to Commissioning of a Gas Pressure-Reduction System

When outlet pressure fluctuates in a gas pressure-reduction system, the cause may not be limited to the regulator itself. Inlet pressure, downstream flow demand, connection integrity, gauge configuration, and commissioning procedures can all affect performance. For a test line with high inlet pressure and a low outlet setpoint, a structured process—parameter verification, model confirmation, installation…

Read More

Case Study: Matching a Pressure Regulator with a Pressure Gauge for Low-Pressure Service

When the outlet pressure of a regulator is low, gauge selection matters alongside regulation performance. If the pressure gauge has an excessively broad range, operators may find it difficult to identify small changes in pressure. A regulator and gauge should therefore be selected as a coordinated system based on the operating conditions. According to the…

Read More

Explosion-Proof Vortex Flow Meter Installation Requirements

When installing an explosion-proof vortex flow meter, the normal requirements for flow direction, straight-pipe conditions, alignment and vibration still apply. In addition, electrical installation in hazardous areas, applicable explosion-protection conditions, wiring and maintenance requirements need special attention. 1. Maintain a stable flow profile First confirm the actual flow direction and make sure the meter arrow…

Read More

How to Select an Explosion-Proof Vortex Flow Meter?

How should an explosion-proof vortex flow meter be selected? The key is to satisfy both the measurement requirements and hazardous-area requirements. In addition to flow, pressure, temperature and pipe size, the selection should consider the hazardous-area conditions, medium properties, applicable explosion-protection requirements, power supply and signal output. For applications involving potentially flammable gases, vapors or…

Read More

How to Select an Installation Location for a Smart Digital Vortex Meter

The key installation considerations for a smart digital-display vortex flow meter include flow direction, straight-pipe conditions, pipe alignment, vibration, installation environment, display orientation and electrical wiring. Because vortex meters rely on a reasonably stable flow profile, the installation location can influence signal quality and operating stability. 1. Confirm flow direction and pipeline conditions Before installation,…

Read More

Separated Vortex Flow Meter Installation Requirements

The key installation requirements for a separated vortex flow meter include flow direction, straight-pipe conditions, pipe alignment, vibration, sensor/display positioning and signal wiring. Vortex meters are relatively sensitive to flow-profile disturbances, so installation should consider not only whether the meter can physically fit but also upstream disturbances, downstream equipment and the surrounding environment. 1. Confirm…

Read More

How Does a Separated Vortex Flow Meter Work?

A separated vortex flow meter works by using the Kármán vortex principle. When fluid passes a bluff body, periodic vortices are generated downstream. The sensor detects the vortex frequency, and the signal-processing unit calculates the flow rate. Unlike an integrated structure, the separated configuration allows the measuring section and display/electronics to be installed separately, which…